Solar On Grid Inverter

Solar On Grid Inverter

  • High Performance : Low Start – up Voltage, wide Voltage Range
  • High Efficient : 97.4% Max. Efficiency
  • Multiple MPPT Design
  • Wide MPPT Voltage Range
  • Compact design for easy installation
  • Touch Key Display
  • Remote Monitoring : Monitor your system remotely via smart phone app of web portal ( via RS 232/Modbus/SNMP/GPRS )
  • IP 65 : Engineered to last with maximum flexibility. Suitable for outdoor installation
  • IEC /BIS  Certified

  • Available Range :

          2, 3, 5 & 6 – Single Phase

          3,5,68,10,12,15,17,20 25,30,33,40,50,60,80,100,110&125              kVA –  Three Phase

  • 10 Year Warranty

Technical Specifications

Nominal power [kVA]

600

500

400

300

250

200

160

Active power [kW] @ 30°C

600

500

400

300

250

200

160

Active power [kW] @ 40°C

540

450

360

270

225

180

144

Flexibility & Scalability

Up to 8 Units (In PR, CE, N+1, Eco Mode Configration)

UPS Topology

Active front end IGBT rectifier & IGBT inverter

Advance control hardware

Advanced dual core 32 bit floating DSP and CAN bus architecture

INPUT

 

Rated voltage [V]

380 / 400 / 415 V AC, 3P 3W

Voltage tolerance [V]

400 ± 20% @ full load1

Frequency [Hz]

50Hz ±12% (60Hz optional)

Power factor

>0.99

Harmonic current distortion [THDi]

<3%

Soft start

0 – 100% in 120 sec. (selectable)

BATTERIES

 

Votage Range

399 to 621V DC

Type

Suitable for SMFB / VRLA / Ni-Cd / LAT Battery / Li-Ion Battery

Charger Type

Automatic float cum boost type (In line with battery type)

BATTERY SAFETY

 

DC MCCB for Battery Bank

Availble with under voltage (UV) trip facility

Temperature compensation at float

Battery manufacturer’s recommendation: -18mV / °C / 12V unit (reference at 25°C)

OUTPUT

 

Rated voltage [V]

380 / 400 / 415 V AC 3P + N (selectable)

Output termination

3P + N, 4W

Static regulation

±1%

Dynamic response

±5% in 10 msec

Voltage distortion [THDv]

<1% with linear load; <3% with non-linear load

Crest factor [lpeack/lrms]

3 : 1

Frequency stability on battery

0.1%

Nominal Frequency

50Hz (60Hz optional)

Overload capacity @ 40°C temperature

250% for 100 msec; 200% for 7 sec;

150% for 1 min.; 125% for 10 min.; 110% for 60 min.

Galvanic Isolation Transformer

Integrated double wound, Zig-Zag galvanic isolation transformer (in-built)

Double conversion efficiency

up to 94% (with isolation transformer losses)

Inbuilt Special Protections

Insensitive to input phase sequence; Input surge protection; Dead short circuit protection

Loading capability

100% Unbalanced load; Regenerative load; Leading and lagging power factor

Emergency Power Off (EPO)

Available

Manual Bypass Switch (MBS)

Make before break type switch with inter-lock facility

OVERALL SPECIFICATIONS

 

Weight [kg]

3500 kg

3000 kg

2500 kg

2200 kg

1900 kg

1700 kg

1600 kg

Dimensions (HxWxD) [mm]

1954x2240x1050

2150x1540x1050

2050x1100x1050

Ambient temperature for UPS Panel

0 °C to 40°C

Recommended temperature for Battery

20 °C to 25°C

Relative humidity

95% non-condensing

Altitude

1000 meter from MSL (higher altitude design on request)

Display

7″ Multi-colored touch screen LCD with multi-langauge selection (optional)

Communications + Remote signaling

Modbus (RS485) + 6 nos dry contacts (field configurable)

Colour

Black grey RAL 7021

Noise level at 1 m [dBA]

< 70 dBA

IP rating

IP20 (higher IP on request)

PCB cards protection

G3 conformal coating

Vantilation

Forced air cooling

Cable Entry

Bottom (top entry optional)

Moving the UPS

Pallet jack

Standards

Safety IEC 62040-1; EMC & RFI IEC 62040-2; Testing / Classification in accordance with IEC 62040-3; IP Protection IEC 60529

Nominal power [kVA]

120

100

80

60

40

30

Active power [kW] @ 40°C

108

90

72

54

36

27

Flexibility & Scalability

Up to 8 units (In PR, CE, N+1, Eco mode configration)

UPS Topology

Active front end IGBT rectifier & IGBT inverter

Advance control hardware

Advanced dual core 32 bit floating DSP and CAN bus architecture

INPUT

 

Rated voltage [V]

380 / 400 / 415 V AC, 3P 3W

Voltage tolerance [V]

400 ± 20% @ full load1

Frequency [Hz]

50Hz ±12% (60Hz Optional)

Power factor

>0.99

Harmonic current distortion [THDi]

<3%

Soft start

0 – 100% in 120 sec. (selectable)

BATTERIES

 

Votage Range

399 to 621V DC

Type

Suitable for SMFB / VRLA / Ni-Cd / LAT Battery / Li-Ion Battery

Charger Type

Automatic float cum boost type (In line with battery type)

BATTERY SAFETY

 

DC MCCB for Battery Bank

Availble with under voltage (UV) trip facility

Temperature compensation at float

Battery manufacturer’s recommendation: -18mV / °C / 12V unit (reference at 25°C)

OUTPUT

 

Rated voltage [V]

380 / 400 / 415 V AC 3P + N (selectable)

Output termination

3P + N, 4W

Static regulation

±1%

Dynamic response

±5% in 10 msec

Voltage distortion [THDv]

<1% with linear load; <3% with non-linear load

Crest factor [lpeack/lrms]

3 : 1

Frequency stability on battery

0.1%

Nominal Frequency

50Hz (60Hz optional)

Overload capacity @ 40°C temperature

150% for 1 min.; 125% for 10 min.; 110% for 60 min.

Galvanic Isolation Transformer

Integrated double wound, Zig-Zag galvanic isolation transformer (in-built)

Double conversion efficiency

Input surge protection; Dead short circuit protection

Inbuilt Special Protections

Insensitive to input phase sequence; Input surge protection; Dead short circuit protection

Loading capability

100% Unbalanced load; Regenerative load; Leading and lagging power factor

Manual Bypass Switch (MBS)

Make before break type switch with inter-lock facility

OVERALL SPECIFICATIONS

 

Ambient temperature for UPS Panel

0 °C to 40°C

Recommended temperature for Battery

20 °C to 25°C

Relative humidity

95% non-condensing

Altitude

1000 meter from MSL (higher altitude design on request)

Display

LCD Display with LED mimic

Communications + Remote signaling

Modbus (RS485) + 6 nos dry contacts (field configurable)

Colour

Black grey RAL 7021

Noise level at 1 m [dBA]

< 70 dBA

IP rating

IP20 (higher IP on request)

PCB cards protection

G3 conformal coating

Vantilation

Forced air cooling

Cable Entry

Bottom (top entry optional)

Moving the UPS

Pallet jack

Standards

Safety IEC 62040-1; EMC & RFI IEC 62040-2; Testing / Classification in accordance with IEC 62040-3; IP Protection IEC 60529

Open chat
1
Scan the code
Hello
How Can we help you?